DEA provided geotechnical engineering and design services for this 4-story tilt up wall building. Subsurface soil conditions required ground improvements: DEA utilized Deep Dynamic Compaction to densify subgrade. Client saved considerably as they did not have to undercut haul off and import replacement structural fill materials.

DEA provided Special Inspection testing and inspection services for the project that included observation of subgrades and foundations, reinforcing and structural steel inspections, installation of utilities, observation and testing of structural fill for the buildings and parking lots, and testing of concrete for the foundations and slab-ongrade.